We are pleased to provide you some of the studies that have been done using the ES Complex and is constitutive modules EIS system and ESO system:
 
Published:
 
Use of Bioimpedance and Chronoamperometry in adjunct to screening of Prostate cancer:
 
 
Use of Bioimpedance in the monitoring of SSRI treatment (brain tissue serotonin marker): 
 
 
 
 
 
 
Other studies:
 
Comparing the accuracy of ES-BC, EIS and ES Oxi results versus the recognized standardized assessment

John E. Lewis1, Janet Konefal1, Angelica B. Melillo1, Evan Long1, Yaima Alonso2, Elizabeth Ko2, Soyona Rafatjah2, and Judi M. Woolger2

1Department of Psychiatry and Behavioral Sciences and

2Department of Medicine University of Miami Miller School of Medicine, Miami, FL 33136

Clinical investigator: John E. Lewis1 , Assistant Professor - University of Miami Miller School of Medicine  

Conclusion: The results of the first study suggest that the ES-BC has a significant level of reliability in estimating body composition and the EIS has a significant level of reliability in estimating the sympathetic nervous system activity. The results of the second study suggest that the ES Oxi has a significant level of reliability in estimating the cardiac output. Software displaying the data of a combination of EIS, ES-BC and ES Oxi devices such as the body composition, autonomic nervous system activity level and hemodynamic indicators will be useful to detect Metabolic Syndrome and its complications and to manage treatment follow up. The software named ES Complex will comprise the entire results of the combination of devices and will manage all the measurements in 2 minutes.
 
 

New marker using the bioimpedance technology in Attention Deficit/Hyperactivity Disorder (ADHD) Children screening in adjunct to the conventional diagnostic methods 

Results:

Independent samples t-test results:

The mean of the 2 pathways at ADHD group was M=33.11µSi (from 2 to 113µSi) was significantly (p<0.001) higher than the mean of 2 pathways at the control group M=2.75µSi (from 1.75 to 27.4µSi).

Receiver operating characteristic curve results:

The parameter mean of conductivity of the pathway between the forehead electrodes has a specificity of 98% and sensitivity of 80 % and p=0.0001 (Upper 95% CI) using a cutoff value at 7.4 µSi.

Conclusion

The EIS marker with the conductivity measurements of the forehead pathway has a high specificity and high sensitivity and the practitioners would have a non-invasive, low-cost, easy to use system in his office, that could offer adjunct results in the conventional diagnosis of ADHD children and valuable tool in the treatment monitoring of this pathology.