We are pleased to provide
you some of the studies that have been done using the ES Complex and is constitutive modules EIS system and ESO system:
Published:
Use of Bioimpedance and Chronoamperometry
in adjunct to screening of Prostate cancer:
Use of Bioimpedance in the monitoring of SSRI treatment (brain tissue serotonin marker):
Other
studies:
Comparing the accuracy of ES-BC, EIS and ES Oxi results versus the recognized standardized assessment
John E. Lewis1, Janet Konefal1, Angelica B. Melillo1,
Evan Long1, Yaima Alonso2, Elizabeth Ko2, Soyona Rafatjah2, and Judi M. Woolger2
1Department of Psychiatry and Behavioral Sciences and
2Department of Medicine University of Miami Miller School of Medicine, Miami, FL 33136
Clinical investigator: John E. Lewis1 , Assistant Professor
- University of Miami Miller School of Medicine
Conclusion: The results of the
first study suggest that the ES-BC has a significant level of reliability in estimating body composition and the EIS has a
significant level of reliability in estimating the sympathetic nervous system activity. The results of the second study suggest
that the ES Oxi has a significant level of reliability in estimating the cardiac output. Software displaying the data of a
combination of EIS, ES-BC and ES Oxi devices such as the body composition, autonomic nervous system activity level and hemodynamic
indicators will be useful to detect Metabolic Syndrome and its complications and to manage treatment follow up. The software
named ES Complex will comprise the entire results of the combination of devices and will manage all the measurements in 2
minutes.
New
marker using the bioimpedance technology in Attention Deficit/Hyperactivity Disorder (ADHD) Children screening in adjunct
to the conventional diagnostic methods
Results:
Independent samples t-test results:
The
mean of the 2 pathways at ADHD group was M=33.11µSi (from 2 to 113µSi) was significantly (p<0.001) higher than the mean of 2 pathways at the control
group M=2.75µSi (from 1.75 to 27.4µSi).
Receiver operating characteristic curve results:
The parameter mean of conductivity of the pathway between the forehead electrodes
has a specificity of 98% and sensitivity of 80 % and p=0.0001 (Upper 95% CI) using a cutoff value at 7.4 µSi.
Conclusion
The EIS marker with the conductivity
measurements of the forehead pathway has a high specificity and high sensitivity and the practitioners would have a non-invasive,
low-cost, easy to use system in his office, that could offer adjunct results in the conventional diagnosis of ADHD children
and valuable tool in the treatment monitoring of this pathology.